Hongqiang Mould logoHongqiang Mould

Cavity Count Cuts the Part Price, Then Melt Balance Takes Part of It Back (8-Cavity Mould, 26.15 mm Measured Spread)

Cavity Count Cuts the Part Price, Then Melt Balance Takes Part of It Back (8-Cavity Mould, 26.15 mm Measured Spread)

← Back to Blog · Cavity Count Cuts the Part Price, Then Melt Balance Takes Part of It Back (8-Cavity Mould, 26.15 mm Measured Spread)

We help buyers pick a cavity count that still pays once tooling, press time and scrap are counted. Published flow studies report a 19:1 flow-rate split inside a geometrically balanced runner, a 26.15 mm fill spread across one balanced eight-cavity tool, and four melt streams inside a 16-cavity mould.

Cavity count is the first number most buyers fix, and it usually gets fixed with a division. Cycle time divided by cavities gives machine time per part, so eight cavities look eight times cheaper to run than one. The quotation stage rarely tests the division any further.

One camp treats extra cavities as free output: double the count, halve the piece price, sign the order. The other camp has received a shipment where cavity three never matched cavity six, and now buys one-cavity tools on principle. Both camps argue about the same number from opposite ends.

Published mould trials sit between them. Runners drawn perfectly symmetric still feed different melt to different cavities, and the measured spread is too large to hide inside a tolerance. One peer-reviewed eight-cavity tool recorded a 26.15 mm difference in fill length between its cavities.

This article works through four questions, using published sources and cross-checking wherever two independent teams reported the same mechanism:

  • What does a cavity count actually buy, and where does the division stop working?
  • Why does a geometrically balanced runner still feed its cavities unequally?
  • How large is the measured spread between cavities on a balanced tool?
  • Which line items in an RFQ keep a multi-cavity mould honest?

The short answer: the division is real arithmetic, but it only pays when the melt stays even, and melt evenness is settled in the runner design rather than in the cavity count. The sections below carry the numbers and the sources.

Key takeaways

  • Machine time: a 30-second cycle drops to 3.75 seconds per part at eight cavities, so the division is genuine arithmetic and worth doing first.
  • Flow groups: an eight-cavity mould fills as two melt streams, a 16-cavity as four, 32 as eight, and 64 as sixteen, on published mould trials.
  • Worst case: reported flow-rate variation between cavities reaches 19:1 when the shear-heated melt wins every branch in the runner.
  • Measured spread: fill-length deviation on one balanced eight-cavity tool ran from 1.3 mm to 26.15 mm depending on resin and gate size.
  • Cheapest lever: opening the gate from 2.03 to 7.42 mm² cut the PP fill deviation from 5.35 mm to 1.3 mm on that same tool.
  • Repair ceiling: melt rotation took one connector from 0.2 mm of cavity-to-cavity variation to under 0.04 mm by redistributing the hot gradients, and the physics stayed.

Methodology

Every figure below comes from documents other teams published, not from a cavity-count study run on our floor. The peer-reviewed backbone is a 2024 study in Polymers that filled a geometrically balanced eight-cavity mould with PP and PC, neat and at 30 percent glass fibre, through two gate sizes, and reported fill-length deviation between cavities together with per-cavity tensile results. The mechanism and the flow-group counts come from John Beaumont, published in MoldMaking Technology in 2012 and in his company’s technical notes on shear-induced variation. The 19:1 flow-rate cases and the connector that improved from 0.2 mm to under 0.04 mm come from a 1998 Plastics Technology report on his SPE Antec presentation. A National Science Foundation project at Lehigh University describes the same mechanism from the academic side.

Where this article computes numbers — machine time per part, clamp scaling — the assumptions sit beside the arithmetic so you can substitute your own. Published sources and shop records stay separate throughout: nothing here was measured in our plant.

Multi-cavity mould plate with cooling ports and inserts checked on the fitting bench
A multi-cavity plate checked at the bench, the last point where the runner layout is still easy to reach

What does a cavity count actually buy?

The purchase is machine time. At a 30-second cycle, one cavity delivers 120 parts an hour, and eight cavities deliver 960 from the same press, so the press cost per part falls by a factor of eight. The mould invoice spreads across every part the tool makes in its life, which is why the same division tempts buyers upward.

The division ignores what happens upstream of the cycle. Every cavity multiplies the shot, the clamp demand, the number of melt streams and the heat to remove, and each of those finds a ceiling on the machine or in the tool.

Cavity count multipliesWhat growsWhere it bites first
Shot volumePart weight × cavities, plus the runner the layout addsInjection unit capacity, before the clamp enters the discussion
Clamp demandProjected area × cavity pressure × cavitiesPress tonnage, as our tonnage article works through
Melt streamsFlow groups double at every split past four cavitiesCavity-to-cavity consistency
Heat and handlingCooling load and parts to remove per cycleThe cycle floor and take-out time

The first two rows are machine selection. The last two decide whether the parts match each other.

That table reads like a sizing exercise, and sizing is the easier half of the decision.

Why does a balanced runner still fill unevenly?

Melt inside a runner flows in laminas, and the lamina touching the wall shears hardest. Shear thins the polymer and friction heats it, so a hot, low-viscosity ring rides along the runner wall while cooler, thicker material fills the centre.

At every branch, that hot ring follows the inside edge of the new leg. Two branches later, cavities fed by a drawn-symmetric layout are receiving melt at different temperatures and viscosities, and they fill at different speeds as a result.

The pattern has a name and a threshold. John Beaumont traced it as the source of filling imbalances in moulds with four or more cavities, easiest to see at eight and above. Four-cavity tools get a quieter version: one side of each part fills hotter than the other, and shrinkage differs across a single piece.

Cavity countMelt streams reported
4One intra-cavity imbalance, side to side within each part
82
164
328
6416

The split repeats at every branch. Eight cavities see two different melts before the first shot is packed out.

The consequences follow in a fixed order on the published record. Cavities fed the hot, fast stream flash while the others are still filling, their parts come out heavier and larger, and the clamp needs more tonnage to hold the tool shut.

Symmetry on the drawing is necessary. The published trials say it has never been sufficient.

How large is the spread between cavities?

The 2024 Polymers study measured it directly on a balanced eight-cavity tool, as the deviation in fill length between cavities at short shot. Gate size moved that number more than anything else the team varied.

Resin, conventional mouldingSmall gate, 2.03 mm²Large gate, 7.42 mm²
PP5.35 mm1.3 mm
PP + 30% glass fibre10.5 mm3.8 mm
PC26.15 mm4.75 mm
PC + 30% glass fibre11.35 mm0.7 mm

Every row shrinks when the gate opens. Small gates starve the outer cavities first, and viscous resins pay the largest penalty.

The extremes agree with the older trial record. Beaumont reported cases where mass flow rate between cavities varied by up to 19:1, and a connector moulder cut cavity-to-cavity variation from 0.2 mm to under 0.04 mm after melt-rotation inserts redistributed the hot gradients at the branches.

The spread reaches beyond dimensions. On that same eight-cavity tool, cavities which over-packed produced PP bars with roughly 280 percent elongation at break, while the under-filled cavities managed about 125 percent, so the cavity number predicted mechanical behaviour as well as size.

Multi-cavity moulded parts from an automotive program laid out in rows on the bench
Parts from a multi-cavity tool laid out in rows, where cavity-to-cavity differences become visible

Those numbers belong to one tool, four resins and two gate sizes. Another geometry lands elsewhere on the same curve, so read the values as an order of magnitude rather than a quota.

What should a multi-cavity RFQ pin down?

The quotation stage is where cavity balance costs least to influence. Four asks separate a balanced tool from an even-looking one:

  • Ask how the runner deals with shear imbalance — melt rotation, a naturally fed layout or another published strategy — and what evidence backs the choice.
  • Ask for the gate sizing rationale with the resin named, since gate area moved the measured spread by a factor of four on the tool above.
  • Ask whether the flow simulation meshes the runners in three dimensions with 12–20 elements through their thickness and includes the machine nozzle, the setup the published guidance says the prediction needs.
  • Ask that every cavity carry a number and that the first-article report key each measurement to the cavity which produced it, because sampling alone cannot prove eight cavities match.

One boundary belongs here. These asks cost the supplier engineering hours, not steel, so a supplier who answers them at quotation is telling you how the tool will be built.

Limitations

Published spreads come from named tools, not from a survey. The 26.15 mm figure belongs to one laboratory mould running tensile bars at two gate sizes, and the same study shows the ranking flip under microcellular moulding. Resin lot, mould temperature and maintenance move the number on a production floor, so treat every value here as a magnitude guide for one condition set.

Third-party figures carry their own scope. The 19:1 flow split, the flow-group counts and the 0.2 mm to 0.04 mm improvement were reported by the researcher who patented the melt-rotation fix, at an SPE conference and in trade media, and labs rarely publish their failures. A university project confirms the mechanism independently, yet none of these numbers was measured in our plant, and this article should not be cited as shop data.

What this means for your RFQ

Cavity count is cheapest to change while the design is still a file. Here, every multi-cavity plate gets its assembly check at the fitting bench, while the runner, the gates and the cooling are still within reach of a spanner.

A cavity count is an economic decision only after the runner design proves each cavity receives the same melt.

We help buyers turn a cavity-count decision into a quotation that names its trade-offs. Design, machining, trials and CMM inspection all happen under one roof, so answers come from the team holding the cutters.

ItemValue
Machine base11 injection presses spanning 80 to 450 T
Tool room5 CNC centres with EDM, grinding and copper electrodes in house
Pre-trial gateMulti-cavity plates get a bench assembly check ahead of the first shot
Trial evidenceBridge CMM dimensional report travels with each trial
Resins in servicePP, PE, ABS, PC and PA
Quotation speedInside 24 hours once the 2D/3D files arrive

Each line above is a published shop fact. Your piece price sits where those facts meet the four limits in this article.

Even melt | Numbered cavities | One plant. Send your 3D file — sales@hongqiangmould.com — and the trade-offs above come back priced, inside 24 hours.

Frequently asked questions

Does doubling the cavities halve the part price? No, and the gap grows with quality requirements. Machine time per part falls with cavity count, but the mould invoice rises faster than linear, and cavity-to-cavity variation adds sorting and scrap the simple division never priced. One balanced eight-cavity tool showed a fill spread of 26.15 mm.

How many melt streams feed an eight-cavity mould? Two, on published mould trials. The first split at the sprue creates one high-shear and one low-shear stream, and every later branch keeps them apart, so four cavities run hot and four run cooler. A 16-cavity tool carries four of these streams, and 32 carries eight.

Does a geometrically balanced runner layout fix the imbalance on its own? No. Equal flow paths equalise pressure drop, but the melt inside those paths is not uniform, because shear heating builds a hot, low-viscosity layer at the runner wall that takes the inside edge at every branch. Melt rotation redistributes the gradients and cuts the measured variation.

What should a dimensional report show for a multi-cavity tool? The cavity number behind every measurement. Parts mixed from eight cavities cannot prove uniformity unless each result traces to the cavity which made it, so ask for cavity identification moulded into the parts and per-cavity results in the first-article report. That turns a pass into evidence.

Jack works on the tooling and molding team at Hongqiang Mould, an injection mould manufacturer and plastic injection molding supplier. The shop runs 11 presses from 80 to 450 T, 5 CNC machining centres and a metrology room with bridge CMM inspection.

Still weighing cavity count at the start of a project? See single-cavity vs. multi-cavity molds: balancing tooling cost, cycle time and volume for a side-by-side decision framework before you request a quote.


Technical Guides

Browse all technical guides →