Hongqiang Mould logoHongqiang Mould

Boss Walls Range From 0.50T to 0.75T in Three Design Guides. Interference, Not Wall, Decides Which One Cracks

Boss Walls Range From 0.50T to 0.75T in Three Design Guides. Interference, Not Wall, Decides Which One Cracks

← Back to Blog · Boss Walls Range From 0.50T to 0.75T in Three Design Guides. Interference, Not Wall, Decides Which One Cracks

Three public design guides answer the screw-boss question with three different numbers. eFunda caps the boss wall under 0.60 of nominal wall. The SABIC LNP guide allows 0.50 to 0.75. DFMPro settles near 0.60 and adds a 0.25 to 0.50 fillet rule. None of the three sets the wall from insert stress.

Every DFM call on a screw boss reaches the same fork. One engineer quotes 0.6T because that is the number in the guide. Another quotes 0.5T because the part carries a class A face and sink marks are already showing.

The first camp treats the boss as a strength feature. The second camp treats it as a mass problem. Both point at published rules, and both are quoting real documents.

The conflict lands downstream, after the insert goes in. A boss that cleared DFM at 0.6T can still split at the bore when a press-fit insert arrives with 0.10 mm of interference. Sink marks and hoop stress pull the same dimension in opposite directions, and most drawings never state which one the buyer is paying to avoid.

Four questions shaped this comparison:

  • Which numbers do the three guides actually specify?
  • How much does wall thickness change insert stress?
  • What boss diameter does each rule produce?
  • Which rule holds on a cosmetic housing with a metal insert?

The short answer: the wall percentage is a sink control, the bore and the interference set the stress, and the drawing should carry both.

Here is the whole case in one paragraph. Take a 4 mm bore in a 2 mm nominal wall with a press-fit insert. At 0.08 mm diametral interference the bore sees 40.4 to 42.9 MPa whether the wall is 0.4T or 0.75T. At 0.12 mm the same bore sees 60.6 to 64.3 MPa, which is the yield point of general-purpose polycarbonate. Wall ratio moves that number by about 6 percent. Interference triples it. A drawing that fixes only the wall ratio fixes the smaller variable.

Key takeaways

  • Rule spread: eFunda and DFMPro cap the boss wall under 0.60T, the SABIC LNP guide allows 0.50T to 0.75T, and the gap is 0.25T on the same feature.
  • Bore controls stress: a 4 mm bore under 0.08 mm interference reads 41.3 MPa at 0.6T against 42.9 MPa at 0.4T, a 4 percent difference for 50 percent more wall.
  • Interference triples it: 0.04 to 0.12 mm diametral interference lifts a 0.6T polycarbonate boss from 20.7 MPa to 62.0 MPa, at the yield line of general-purpose PC.
  • Geometry follows the fastener: boss OD equals bore plus twice the wall ratio times nominal wall, so a 4 mm bore at 0.6T on a 2 mm wall lands at 6.4 mm.
  • Shop split: cosmetic faces keep 0.5T plus gussets, insert bosses go 0.6T to 0.75T with a cored base, and the bore is gauged on our bridge CMM before trials.

Methodology

Two inputs feed this piece. The first is the published rule set: the eFunda Boss Design standard page, the SABIC LNP specialty compounds design guide, and the DFMPro injection moulding guideline. The second is a thick-wall cylinder calculation run on one geometry family, a 4 mm bore in a 2 mm nominal wall, across wall ratios from 0.4T to 0.75T.

Guide values are quoted as published, with links at the foot of the page. Stress values are computed, not measured: plane stress, rigid steel insert, linear elastic polycarbonate at E = 2400 MPa and Poisson ratio 0.37, no creep, no temperature rise. Shop references below describe the process route in our plant: tooling on 5 CNC machines, EDM and a bridge CMM room, plus production moulding spread across 11 machines rated 80 to 450 T. They are not a test series.

What do the three design guides actually specify?

Each guide states one number for the boss wall and a different reason for it. The reason matters more than the number.

GuideBoss wall, as a multiple of nominal wallWhat the number is tied to
eFunda, Boss DesignUnder 0.60, thicker allowed on hidden wallsSink marks on visible surfaces; extra wall permitted where a self-tapping screw loads the boss
SABIC LNP design guide0.50 to 0.75Stress inside the boss wall, with the ratio chosen against that stress
DFMPro boss guidelineAbout 0.60, capped at 0.60Sinking, plus a 0.25 to 0.50T base fillet, a height below 3 times boss OD and spacing of at least 2T

Read only the middle column and the guides look 0.25T apart. Read the right column and they are answering different failures.

The extra geometry rules travel together in practice. A 0.60T boss standing 40 mm tall on a 6 mm outer diameter is a cooling problem regardless of its wall. That is why the height limit and the spacing rule belong on the same drawing callout.

Moulded housing with deep ribs and screw bosses after a trial run

Bosses on a moulded housing, photographed here after a trial run. The face behind each boss is the surface that shows a sink mark first.

Why does a thicker boss wall barely reduce insert stress?

The bore is the loaded surface. A press-fit insert pushes outward and the boss answers as a thick cylinder. Hoop stress at the bore follows a standard closed-form solution, with K built from the bore radius a and the outer radius b. Diameter enters through K, and K flattens quickly once the wall grows.

Diametral interference0.40T wall, OD 5.6 mm0.60T wall, OD 6.4 mm0.75T wall, OD 7.0 mm
0.04 mm21.4 MPa20.7 MPa20.2 MPa
0.08 mm42.9 MPa41.3 MPa40.4 MPa
0.12 mm64.3 MPa62.0 MPa60.6 MPa

Conditions: 4 mm bore in a 2 mm nominal wall, polycarbonate at E = 2400 MPa, Poisson ratio 0.37, steel insert treated as rigid.

Triple the interference and the stress triples with it. Add wall and the curve barely moves.

General-purpose polycarbonate yields around 62 to 67 MPa. The 0.12 mm row therefore sits at the yield line for all three walls, which is why a cracked boss usually points at the insert fit rather than at the wall percentage. The calculation does not cover every case, and a self-tapping screw is the clearest exception: thread-forming displaces resin locally around each thread, so a smooth-cylinder model overstates the stress it creates.

How does each rule change the boss you draw?

The geometry is simple once the fastener is fixed. Boss outer diameter equals bore plus twice the wall ratio times nominal wall.

Wall ratio4.0 mm bore, 2.0 mm wall4.0 mm bore, 2.5 mm wall5.0 mm bore, 3.0 mm wall
0.40T5.6 mm OD6.0 mm OD7.4 mm OD
0.50T6.0 mm OD6.5 mm OD8.0 mm OD
0.60T6.4 mm OD7.0 mm OD8.6 mm OD
0.75T7.0 mm OD7.75 mm OD9.5 mm OD

Move from 0.5T to 0.75T on a 3 mm wall and the boss grows 1.5 mm in diameter. That extra ring of steel is what turns into a sink mark.

The table also shows why the 0.75T option needs a design reason. It adds mass at the base, and the base is where the cosmetic face sits.

Eight-cavity family strip of grey moulded parts laid out for dimensional sampling

An eight-cavity strip laid out for dimensional sampling. Boss height variation between cavities shows up here before it reaches assembly.

Which boss design holds on a cosmetic housing?

Split the decision by failure mode, not by convention. A boss under a visible face is a sink problem; a boss holding a metal insert is a stress problem; a boss doing both needs a cored base and a compromise ratio.

  • Visible face, no insert: 0.50T wall, 0.25T base fillet, gussets instead of a thicker ring.
  • Insert with pull-out load: 0.60T to 0.75T wall, and set the interference before the wall. A 0.10 mm diametral fit on a 4 mm bore is already near the limit for PC.
  • Repeated service: heat-set or ultrasonic insert. The resin softens, yields and relaxes around the knurl, so the cold press-fit strain path no longer applies.
  • Both conditions at once: core the base, step the wall below the insert depth, and keep the fastening load in a region with no cosmetic surface behind it.

Our route for these parts runs boss cavities and bores on copper electrodes in the EDM room, then checks bore diameter and position on the bridge CMM before trials. Multi-cavity plates get a bench check at assembly, where boss height spread across cavities is the defect that surfaces first. From a 40 g connector boss to a 1 kg housing with six inserts, interference and wall are separate callouts.

Limitations

The stress figures are arithmetic, not measurement. No strain gauges, no pull-out rig and no sectioning were used, so the numbers show the mechanism and the ranking of variables, not the exact stress in a given moulding.

Real behaviour departs from the model in three ways. Viscoelastic relaxation drops the stress over hours and days, mould temperature changes the modulus, and a textured or glass-filled grade behaves differently from the unfilled polycarbonate used here.

The rule values come from three third-party sources published for general guidance. eFunda, SABIC and DFMPro set their limits for different applications, and none of them inspected the part on your desk. Material constants are typical datasheet values for polycarbonate, not certified test data from our plant.

What this means for your RFQ

We help product teams turn a housing model into a tool that survives insert fitting. That starts with two numbers on the drawing instead of one: the boss wall ratio and the interference the insert will see.

Send the fastener spec, the insert diameter with tolerance, the nominal wall and a note on which faces are cosmetic. Mail it to info@hongqiangmould.com and we will size the boss, flag the sink risk and quote back within 24 hours. Bosses that arrive with a fastener spec rarely come back for rework.

One rule of thumb survives the whole comparison. Size the wall for sink, size the bore for the insert, and never use one number to do both jobs.

Cored | Gauged | Quoted in 24 hours

Frequently asked questions

Is 0.6 times nominal wall the right boss wall for a metal insert? Only as a starting point. The 0.60 figure comes from sink control on visible walls, not from insert stress. A press-fit insert with 0.08 mm diametral interference already loads a 4 mm bore to about 41 MPa in polycarbonate. Thicker walls add stiffness and mass, and they leave that hoop stress almost unchanged. Set the interference first.

Why do design guides disagree between 0.50 and 0.75? They optimise different failures. eFunda and DFMPro write for sink marks on cosmetic faces, so they cap the wall near 0.60. The SABIC LNP guide writes for stress in the boss, so it allows 0.75 where the load demands it. Both rules are usable. The drawing has to state which failure matters.

Does a heat-set insert change the calculation? Yes, and the cylinder model stops applying. A heat-set insert goes in at a temperature that softens the resin, so the polymer yields and relaxes around the knurl instead of storing elastic strain. A cold press-fit keeps that strain. For repeated service and pull-out load, heat-set or ultrasonic inserts are the safer route.

What should I put on the drawing for a screw boss? State the fastener, the pilot or insert diameter with tolerance, the interference you expect, and whether the face behind the boss is cosmetic. Then give the nominal wall. With those four values a toolmaker can size the boss, pick the fillet and flag sink risk before steel is cut. Missing sizes cause most boss rework.

Jack works on the tooling and molding team at Hongqiang Mould, a mould shop in China that builds injection moulds and runs production moulding on 11 presses from 80 to 450 T. He writes about the numbers behind tooling decisions: clamp force, cooling, ejection and the tolerance stack that decides whether a part assembles.

Sources

Boss Design. eFunda, https://www.efunda.com/designstandards/plastic_design/boss.cfm.

LNP Specialty Compounds Design Guide. SABIC, https://www.sabic.com/en/products/documents/lnp-konduit-compounds-portfolio-introduction/en.

Design Guidelines for Bosses. DFMPro, https://dfmpro.com/manufacturing-processes/dfmpro-for-injection-molding/2/.


Technical Guides

Browse all technical guides →

/* data-no-optimize is REQUIRED: LiteSpeed rewrites plain inline scripts to type="litespeed/javascript", which browsers never execute. This site's existing inline scripts already use the same attribute. */